Volume 2, Issue 3, September 2017, Page: 76-79
System Monitoring of the Emotional State of Students in High School
Nuru Safarov, Department of Electronics and Telecommunications Engineering, Khazar University, Baku, Azerbaijan
Netavan Haydarova, Complex School-Lyceum - MLK, Baku, Azerbaijan
Received: Dec. 15, 2016;       Accepted: Feb. 15, 2017;       Published: Mar. 3, 2017
DOI: 10.11648/j.ajdmkd.20170203.11      View  1736      Downloads  121
Abstract
The resistance of skin is measured by means of special elastic bracelet which is connected to fingers and then is transmitted to measuring device. The control is based on the method of measurement impedance of students. After this, the detected signal from output of the measuring device is sent to PC. Special software treats this information and diagnoses the students. This system is basically able to: to determine the emotional status of students; to create daily archive database for each student; to make analysis accordingly to this archive.
Keywords
Correction, Signal, Impedance, Controlling System, Emotional State
To cite this article
Nuru Safarov, Netavan Haydarova, System Monitoring of the Emotional State of Students in High School, American Journal of Data Mining and Knowledge Discovery. Vol. 2, No. 3, 2017, pp. 76-79. doi: 10.11648/j.ajdmkd.20170203.11
Copyright
Copyright © 2017 Authors retain the copyright of this article.
This article is an open access article distributed under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Reference
[1]
D. C. Smith. “Effects of skin blood flow and temperature on skin-electrode impedance and offset potential: measurements at low alternating current density” J Med Eng. Technol., Vol. 16, No. 3, pp. 112-116, 1992.
[2]
M. A. Liebert. “Electrical Skin Impedance at Acupuncture Points”, the Journal Of Alternative And Complementary Medicine Volume 13, Number 4, pp. 409-418, 2007. Inc. DOI: 10.1089/acm.2007.6258
[3]
N. A. Safarov, S. S. Amirov, F. A. Ahundova. “Automatic System Of Connection Of The Electrostimulator On The Skin Impedance” The Journal Physics NAS, 2004, v. X, #1, 2, pp. 40-42.
[4]
A. A. Bayramov, N. A. Safarov. Automated system for control and correction functional state of human.5th international conference on Application of Information and Communication Technologies, 12-14 October 2011, Baku, Azerbaijan, 208-210.
[5]
AN. Remizov. Physics, electronics and cybernetics course. High School, Moscow, 1982.
[6]
N. A. Safarov, E. M. Rzazadeh, I. Q. Aliev, H. G. Hassanov. Controlling system for emotional state of working personne l.7th international conference on TPE (ICTPE-2011), Lefkosa, TR Northern Cyprus, 7-9 July, p. 553-555. 2011.
[7]
N. Daniklova, A. Krilova Physiology of Higher Nervous Activity: Textbook M.: Moscow University, 1989. (in Russian)
[8]
V Druzhinin. Experimental Psychology of St. Petersburg: "Peter" Publishing House, 2000. (in Russian)
[9]
L. Grimak, A. Skrypnikov, A. Lagovskiy, I. Zubrilova. Methods of Applied Psychology in the detection and investigation of crimes. Tutorial. M Research Institute of the Russian Interior Ministry, 1999. (in Russian)
[10]
A. Skrypnikov, I. Zubrilova, S. Zerin. Technique and tactics of polygraph application in solving crimes: Toolkit. - M.: Institute of the Russian Interior Ministry, 1997. (in Russian)
[11]
Yu. I. Cholodniy. The use of polygraph in the prevention, detection and investigation of crimes. M.: "Safety World". 2000 160p. (in Russian)
[12]
Nuru Safarov. Polymer - Silicon Sensor for Determination Flow. Global Journal of Engineering Science and Research Management. 3(9): September, 2016, p. 19-21.
Browse journals by subject